Ukraine Trade Data of Wa Imports Under HS Code 8416

Lookup Ukraine trade data of wa imports under HS code 8416. Check Ukraine import trading parters of wa

 
shipment icon

5 Shipments Records (Demo)

8416  
DateHS CodeProduct DescriptionOrigin CountryQuantityUnitNet WeightTotal Value [USD] Importer Name
27/Apr/20178416201000"1.palnyky gas supplied to the fan and a device to control: gas burners dvoblochnyy (fan, control cabinets and a separate burner unit included) model: amr-5-g / fm-2-5-t -1sht.dovzhyna flame tube l = 800mmartikul: 942-033 serial number: 37073teplova power: 6mvt, gas pressure: 200-350mbar, costs of gas, 635 nm3 / chas.avtomatyka management - etamatic lamtecmodel: amr-7-g / fm-2-5-t - 1sht.dovzhyna flame tube l = 800mmartikul: 942-032 serial number: 37074teplova power: 9mvt, gas pressure: 200-350mbar, waste gas: 1, 150 nm3 / chas.avtomatyka management - etamatic lamtecvyrobnyk: "" gb-ganz tuzel�estechnikai kft "" country of origin: european union (eu) .torhovelna mark: gb-ganz.. "N/A2UA1101201,23051,020.75 ***** 16 More Columns Available along with Company Name and Other Details etc.
19/Apr/20178416109000"1. gas burners type noxmat rhgb oven for 25 aichelin 2384- 3pc. designed for high-temperature heating section of the heating furnace. the burner is made of austenitic steel type 2h20n9t supplied unassembled for correct installation of bearing elements of the furnace. the burner adapted to supply natural zaatozovanym gz35 gas type. the burner has two electrodes: spalahnennya and ionization are connected to the control system of the furnace. spalahnennya electrode is used to fire the mixed gas and air. the ionization electrode acts as a transducer n�lum'ya. the burner also has a partition for manual regulation of primary and secondary air. the air required for combustion gas is supplied to the burner discharge fan. the burner is installed in the furnace using the mounting flange and teploizolyuyetsya stone palnykakonstruktsiya burner 1 korpus2 shafy3 drive bracket for gas yield.4 fan + uschilnennya5 pipe (tube fire) 6 electric drive (spalahnennya electrode) 7 fuse (e lektrod ionization) 8 holovkytehnichni characteristics: thermal power 25kvt, 5kpa gas pressure, air pressure�6kpa, maximum temeperatura 1150s.tovar was not in use.�year - 2017. packed in trees "" yanyy box.�trademark: riva.�producer: "" riva sp.zoo "", pl. "POLAND3UA20509013516,636.03 *****
11/Apr/20178416201000"1.palnyky with integrated gas. device management for (in a disassembled state in thies, complex components), industrial, gas space heating systems weishaupt: -wm-g30 / 2-a vykon.zm, r2 (s / n: 40414899 - 40414901) complete with equipment, art. 21731213 -3sht. (each kit consists of: relay maximum pressure hazugw150 a6 / nd-1 support in the groove. vic., art. 25003331-1sht, ball kranhazovyy 984d-2 pn40 / mop5 t�ufles .uschil., art.454664-1sht; gas filter 2 rp wf520 / pb 0, 5bar 1, art. 15122340160-1sht, gas pressure regulator frs 520 rp 2 vklyuch.pruzhynu tension spring with a black 60-110 mbar, art. 15133026892 -1sht, gauge 0-400mbar f.z sti�coy and tap vykon.a g1 / 4 art.15133626792-1sht; 0-160mbar gauge of stiyk.i cranes, and g1 / 4 ad.gw a5, art.15133626892-1sht, doppel-nipple r 2 x 120 art . 13900026697 -3sht, connecting elementywm30, g, gl, rgl, rgms9u.10, art. 15190700012 -1sht, cable mount wm30 3xm32, 4xm20, art. -1sht 21131400522; loop connector, art. 343 299 -1sht; warning sign regulated gas pressure modulator rus, art.�736500 -1sht;�relay tyskugw 50 a5 / 1 5-150mbar, art.691378-2sht;�pressure switch gw 150 a6 / 1 10-150mbar, art.691382 -1sht;�connection kit for r2 relay max.�pressure art.�15133726192-1sht;�fasteners gas throttle valves, art.�-1sht 21750526022, corresponding flange dn 80 - rp 2, art.�15133626207 -1sht;�set rebar r2palnyk-nw dn50- dn80, art.�21705026042 -1sht;�dual magnetic valve hazovyydmv 220-240v 525/12, art.�625040 -1sht.) .- wm-g10 / 4-a done.�zm r2 (s / n: 40415906 - 40415908) complete with equipment, art.�21712013 -3sht.�(each kit consists of: extension polumyanoyi golovin 100mm wm-g10 / 4 zm, art.25003009-1sht, gas pressure regulator frs 520 chorn.pruzh.10-30mbar rp2, art.15133026892-1sht, rp 2 gas filter wf 520 / 1 0, 5bar pb, art.15122340160-1sht, doppel-nipple r 2 x 120, art. 13900026697-2sht: relay tyskuhazu gw 150 a4 30-150mbar, art.691356-1sht, doppel-nipple r 1/4 x 50 , art.13900026017-1sht, fasteners wm10, g5, gl5, rgl5, art. -1sht 15131600042; loop connector, art. 343 299 -2sht, cable mount 2xm32, 5xm20 wm10, art.21110400522 -1sht, relay pressure gw 50 a5 / 1 5-50mbar, art.691378 -1sht, warning sign gas pressure regulator rus, art.736500 -1sht, and fasteners�rmatury gas throttle, art. -1sht 15150626022; flanetsvidpovidnyy dn50 din en 1092-1 / 13 / b1, art. 452 921 -1sht, a set of valves r2palnyk-nw dn50-dn80, art. 21705026042 -1sht, double magnetic valve hazovyydmv 525/12 220-240v, art. 625 040 -1sht.-wm-g20 / 2-a execu. zm r2 (s / n: 40415910) supplied with the equipment, art. 21721113-1sht.�(each kit consists of: gas pressure regulator frs 520 rp 2 of chornoyupruzhynoyu 10-30mbar, art.15133026892-1sht; gas filter rp2 wf 520/1 pb 0, 5bar, art.15122340160-1sht, doppel-nipple r 2 x 120 , art. 13900026697-2sht; tyskuhazu relay gw 150 a4 30-150 mbar, art.691356-1sht, doppel-nipple r 1/4 x 50 art.13900026017-1sht, fasteners wm20, g, gl, rgl , rgms7 u.8, art.15170700012 -1sht, lock washer 10 d "GERMANY17UA1002102,04987,793.12 *****
04/Apr/20178416208000"1.palnyky flue gas (components for central heating boilers): a pilot gas burner without automatic control device steel for continuous flow water heaters mag art.042198 -2sht, country of detorhovelna vaillantvyrobnyk brand vaillant gmbh."GERMANY******UA3051000.1021.49 *****
12345...90NextGoTo:
Need to access complete data?
loading icon

Get global trade data online at your fingertips

  
TERMS & CONDITIONS     |    CANCELATION POLICY     |    REFUND POLICY     |     PRIVACY POLICY
Copyright © 2021 Export Genius. All rights reserved