Ukraine Trade Data of Emission Spectrometer Imports Under HS Code 90

Lookup Ukraine trade data of emission spectrometer imports under HS code 90. Check Ukraine import trading parters of emission spectrometer

 
90  
DateHS CodeProduct DescriptionOrigin CountryQuantityUnitNet WeightTotal Value [USD] Importer Name
25/Apr/20179012109000"1.rastrovyy electron microscope jsm-it300lv (unassembled) -1sht. (microscope jsm-it300lv is a scanning electron microscope with the ability to work unyzkovakuumnomu environment. raster optics is the formation of images of individual elements using different poyednuv ment transparent and non prozoryhreshitok ( raster), transforming directed beam. scanning elektronnyymikroskop consists of the following uzliv: -electronic gun emityruyuschaya electrons; -console kolonoy with vacuum system and electron-optycheska-system electric formyruyucha�throne beam and provide yvayuschayoho skanyruvannya the surface zra cad (personal computer, ridkokrystal ychnyydyspley) interface for external second control scan software internalcontrol, control module, the module image spare, camera samples lateral camera dlyaohlyadu camera samples - control system gateway, gateway s ra, the system of vacuum chamber, secondary electrons detector for low vacuum mode detector strumupuchka; -�nerhodyspersiynyy ch ektrometr, vds spectrometer (turret 6 crystals) -krystaly, membranes, gaskets, rubber�caps to goggles, adapters, and other kabelizhyvlennya flexible svitlovid set standards, an additional lens cathodes; -stil operator.�mikrokop equipped with comfortable stuvalnyminterfeysom clear bark.�has vysokuproduk ness by vysokoshvydkistnoho with tolykazrazkiv and management capabilities using the touch screen as supplemented nennyado high electron optics to improve the system vacuum system vidkachkyi capture and image building.�features: // cathode type dzherelaelektroniv direct nacala tungsten;�nyzkovakuumnyy mode of 10do // 650 // pa spatial resolution at 30kv 3 nm, at 15nm 1kv;�prostoroverozriznennya in nyzkovakuumnom mode // 4nm;�the energy of the electron beam // 300 ev to 30 kev;�// increase from 5 to 300, 000 krat on the print formatu10h15sm;�// jet beam from 1pa to 1mka;�// maximum sample size 20mm diameter and 80mm thickness;�table // evtsentrytsnyy samples, motoryzo tion zusih (five) kordynat with dyapazo nnym travel x 125mm, y-100mm, z-80mm, naklon- 10 to 90hradusiv, swing the 360-degrees without the stop;�systemavakuumnoyi // turbomoleku polar evacuation pump forvakuumni pumps;�// systemashlyuzovannya option.�the microscope is based on a pre sformovanohotonkoho electron beam (probe), the situation is managed by dopomohoyuelektromahnit these fields.�under the influence of the electron beam is a series of processes specific to the material and its structure.�these vidnosytsya rozsiyanipervichni elect ktrony, ispuskannya (emissions) secondary electron poyavaelektroniv passing through the object (in the case of thin objects) vyneknennyaharakterezuyuchoho radiation.�purpose microscope: - an image surface with nanometer resolution; - local determining the content of a wide range of chemical compounds and materials (ceramics, alloys, polymers) software: control mikroskopomzdiysnyuyetsya "JAPAN******UA112020980.90980,000 ***** 16 More Columns Available along with Company Name and Other Details etc.
25/Apr/20179027300000"1.optychnyy eshellye spectrometer with inductively coupled plasma model icap 7000duot.m.thermo fisher scientific, nastilnamodel dual supervision plasma (axial and radial): optical emission spectrometer with indu ctively coupled plasma icap 7000duo-b / a, the number of -1sht. specifications: optical character range 166-847 nm. - spectral resolution zdatnist0, 007nm.pry wavelength of 200 nm. - tor was detected using solid state semiconductor measuring lines; -fully upravlyayeme coupled plasma source induktyvno- equipped heneratorom27 , 12mhts.z auto arson plasma; -prohramne provide�ting iteva in nine languages; -system input sample consists w lyuvacha, sklorozpodilchoyi camera takvar- zeboim plasma horyelky; -system input vysokosolevyh solutions; -prystavka generation of volatile hydrides; -zvolozhuvach argon for use with high solevymy solutions - the gas reducer for argon pidimknennya; -tsyrkulyator water closed; -paket validation (iq / oq) with a set of spare parts, consumables and komplektomteh.dokumentatsiyi.vyrobnyk's material: thermo fisher scientific (cn) .torhivelna brand: thermo fisher scientific "CHINA******UA125100250105,133.39 *****
11/Apr/201790273000001.prinology for physico-chemical analysis: icp-oes agilent 5110 vdv atomic emission spectrometer: atomic emission spectrometer icp-oes agilent 5110 vdv with vertical double-overview of icp expert software software, 3-channel overheating pump and installed gas module №. g8015aa, -1 pieces. cooling system cat. № g8481a, -1 pieces. argon honeycomb with connectors for argon humidifier cat № g8488a, 1 piece. icp expert pro software number g9562aa, 1 piece. not a medical purpose, for a chemical laboratory, does not contain sources of radioactive radiation.�.N/A******UA12510021546,017.79 *****
12345...90NextGoTo: