30/Nov/2017 | 8544609009 | High-voltage wires (voltage up to 1000 v) with nemednym conductors for spark plugs cars not contain precious metal, fire-resistant, it comes complete | UKRAINE | TESLA | *** | *** | 6.70 | 468,77 | ***** | 84 More Columns Available along with Company Name and Other Details etc. |
23/Nov/2017 | 8544609009 | Tires pf / cs (dc) for the poloidal coils and the central solenoid. maximum dc current 55 ka class insulation 13.2 kv ac, is designed to connect | FRENCH REPUBLIC | ITER | *** | *** | 5,105 | 118354,51 | ***** |
17/Nov/2017 | 8544609009 | Cables, insulated 10 kv, with aluminum conductors, without the contents of precious metals, with no connecting devices, for power transmission at a distance of: | UKRAINE | ABSENT | *** | *** | 85.50 | 297,31 | ***** |
29/Sep/2017 | 8544609009 | Insulated electrical cables for voltage kv 10-15 with aluminum conductors, without the contents of precious metals, without connecting means marks apvegazhpu 1h95 / 35tal-15 (7110 m), tu 16.k180-014-2009. the cables are designed for installation in c: em | RUSSIA | *** | 12,434 | KG | 12,434 | 35886,9 | ***** |
29/Sep/2017 | 8544609009 | Insulated electrical cables on voltage of 35 kv with aluminum conductors, without the contents drag.metallov without connecting means marks apvpug 1x50 / 16-35 (6418 m) tu 16.k180-014-2009 intended for laying in the ground. : ooo "kamsky cable" | RUSSIA | *** | 7,162 | KG | 7,162 | 25901,84 | ***** |
27/Sep/2017 | 8544609009 | Electrical conductors: the conductor consists of separate sections, delivered unassembled for easy transportation. designed to perform electrical connections for power stations and substations electrical conductors tenp-24-24000-560 u1 with side | RUSSIA | *** | 2414,25 | KG | 2,414.25 | 33753,26 | ***** |
11/Sep/2017 | 8544609009 | Insulated electrical cables 10 kv with aluminum conductors, without the contents drag.metallov without connecting means marks asbl 3h240 (oj) -10 (m 1677), 3h185 (oj) -10 (627 m) gost 18410-73 intended for transmission and distribution: el | RUSSIA | *** | 15,297 | KG | 15,297 | 32647,42 | ***** |
06/Sep/2017 | 8544609009 | Wires and cables with insulated aluminum conductors with nominal cross-section 185mm2, for voltage 10000v are free superconducting filaments, intended for transmission and distribution of electric energy in stationary installations on the cable apvpu2g | RUSSIA | *** | 15,000 | KG | 15,000 | 92620,95 | ***** |
05/Sep/2017 | 8544609009 | Tires pf / cs (dc) for the poloidal coils and the central solenoid. maximum dc current 55 ka class insulation 13.2 kv ac, is designed to connect winding poloidal field and the central solenoid iter c & | RUSSIA | *** | 10,340 | KG | 10,340 | 154370,74 | ***** |
05/Sep/2017 | 8544609009 | The cables are intended for transmission and distribution of electric power in stationary equipment in networks of up to 10 kv 50 hz. cable aab2l 10 kv veined 3x with section 120 sq.mm. design elements: the presence of al | RUSSIA | *** | 1,430 | KG | 1,430 | 7355,27 | ***** |